Toshiba MA-1650-4 Cash Register User Manual


 
4. READ AND RESET REPORTS
EO1-11110
4-9
4.3 OPERATIONS AFTER IN-LINE REPORT TAKINGS
4.3 OPERATIONS AFTER IN-LINE REPORT TAKINGS
The following operations are available after taking in-line reports.
CONSOLIDATED REPORT DATA READ (REPRINT)
This operation issues the report data which is remaining in the Consolidation Memory of the Master Terminal.
OPERATION ON MASTER TERMINAL: Mode Lock: X/RTR Declaration: ON
90 [AT/TL]
When no consolidated data are remaining in the memory, this read operation is unavailable.
ENFORCED CLEAR OF HOLD CONDITION (on Individual Terminals)
This can be operated when the HOLD condition on a terminal can by no means be cleared because the terminal
cannot receive a Clear Command from the Master Terminal for some reason (the Master Terminal becomes
down, etc. before completion of the reset report data collection).
OPERATION ON ANY TERMINAL IN HOLD CONDITION: Mode Lock: Z
9999 [AT/TL]
On operating this, the HOLD condition is cleared, and allowing any key-in operations. However, this operation
is regarded as an emergent measure to cope with such a trouble as the Master Terminal becomes down, etc.
and thus no other solutions can be chosen, because the sales data memory of those reports can no longer be
collected by the Master Terminal.