Tripp Lite 932845 Switch User Manual


 
30
9. Windows Client
(
continued
)
9.4.3 Panel Array Mode
(
continued
)
9.4.4 Multiuser Operation
Panel Array Toolbar•
The Panel Array toolbar, at the lower right of the screen, provides shortcut navigation and control of the panel array as described in the table below:
Multiuser Operation
TheNetDirectorConsoleKVMSwitchwithIPAccesssupportsmultiuseroperation.Upto32userscanloginatthesametime.Whenmultipleusers
simultaneouslyaccesstheKVMswitchfromremotecomputers,therulesofprecedencethatapplyareshowninthefollowingtable:
Operation Rule
General Once a user invokes the OSD, no other user can invoke it until the original user closes it.
Auto Scan Mode
If a user has invoked Auto Scan Mode, but the OSD has not been invoked, another user can interrupt Auto Scan Mode by invoking
the OSD.
Panel Array Mode
When a user has invoked Panel Array Mode, all successive users automatically enter Panel Array Mode. Panel Array Mode •
continues until the original user stops it. (Administrators can override Panel Array Mode.)
Only the user who starts Panel Array Mode can use the Skip Mode (see section 9.4.3) function.•
Only the user who starts Panel Array Mode can switch ports. Other users automatically switch to the ports that the original user •
selects. However, if an individual user does not have access rights to the port that the original user switches to, the user will not
be able to view that port.
Individual users can increase or decrease the number of panels they wish to view in Panel Array Mode; however, the picture •
quality may decrease as the number of panels decreases.
9.4.5 Keyboard Hotkey Operation
KeyboardhotkeycombinationsallowyoutoprovideKVMfocustoaport
directlyfromthekeyboard.TheNetDirectorConsoleKVMSwitchwith
IP Access hotkey features are described in the following sections.
Auto Scanning
The Auto Scan function automatically switches among all the ports that
are accessible to the currently logged on User, so that the user can monitor
their activity automatically. (See Scan Select
,section7.4,forinformation
regarding accessible ports.)
Setting the Scan Interval
The amount of time Auto Scan dwells on each port is set with the Scan
Duration
setting(seesection7.4).
Invoking Auto Scan
TostartAutoScanning,opentheOSDtoolbarbypressingyourchosen
hotkey twice (either Scroll Lock or Ctrl), and then tap the A key. The Auto
Scanfunctioncyclesthroughtheportsinorder-startingfromtherstport
on the installation. An SappearsinfrontofthePortIDDisplaytoindicate
thattheportisbeingaccessedunderAutoScanMode.
Pausing Auto Scan
WhileyouareinAutoScanMode,youcanpausethescanningand
focus on a particular computer by pressing P.Duringthetimethat
Auto Scanning is paused, the SinfrontofthePortIDblinksonandoff.
Pausing when you want to keep the focus on a particular computer is
moreconvenientthanexitingAutoScanModebecausewhenyouresume
scanning, you start from where you left off. If you were to exit and restart
AutoScanMode,thescanningwouldstartfromtheveryrstcomputer
on the installation. To resume Auto Scanning after pausing, press any key
except Esc or the Spacebar. Scanning continues from where it left off.
Exiting Auto Scan
WhileAutoScanModeisineffect,ordinarykeyboardfunctionsare
suspended.YoumustexitAutoScanModeinordertoregainnormal
controlofthekeyboard.ToexitAutoScanMode,pressEsc or the
Spacebar.AutoScanningstopswhenyouexitAutoScanMode.
Skip Mode
SkipModeallowsyoutoswitchportsinordertomonitorthecomputers
manually. You can dwell on a particular port for as long or as little as you
like-asopposedtoAutoScanning,whichautomaticallyswitchesafter
axedinterval.TheSkipModehotkeysarethefourArrowkeys.Just
aswiththeAutoScanHotkeys,youmustrstopentheOSDToolbarby
pressing your chosen hotkey twice (either Scroll Lock or Ctrl) in order to
usetheSkipModehotkey.Theiroperationisexplainedinthetablebelow:
Hotkey Action
Skips from the current port to the first accessible port
previous to it.
Skips from the current port to the first accessible port
that comes after it.
Skips from the current port to the first accessible port
on the installation.
Skips from the current port to the last accessible port
on the installation.
Icon Function
Click and drag to move the toolbar to another position on
the screen.
Pause panel scanning, leaving the focus on the panel
that currently has it.
Move the attention of the panel array mode scan back
four panels.
Move the attention of the panel array mode scan to the
previous panel.
Move the attention of the panel array mode scan to the
next panel.
Move the attention of the panel array mode scan ahead
four panels.
Increase the number of panels in the array.
Decrease the number of panels in the array.
Toggle 4/3 aspect ratio for widescreen monitors.
Exit Panel Array mode.
Note: For issues affecting multiple user operation in Panel Array Mode, see section 9.4.4, MultiuserOperation.