Appendix
Status Read Command
Format
The command is sent from PC to the projector with
the format below;
‘CR’ [Command] ‘CR’
Command: one character (refer to the command
table below.
The projector decodes the command and returns the
‘Character string’ with the format below;
Command Function
Projector
Return
Projector status
CR0 Status Read
00 Power On
80 Stand-by mode
40 Countdown
20 Cooling down
10 Power Malfunction
28 Cooling down at the temperature anomaly
88
Stand-by mode after Cooling down at the temperature
anomaly.
24 Cooling down at Power Management mode
04 Power Management mode after Cooling down
21
Cooling down after the projector is turned off when the
lamps are out.
81
Stand-by mode after Cooling down when the lamps
are out.
CR6
Temperature
Read
%1 %2 %3
%1 = Temperature at Sensor 1 (˚C)
%2 = Temperature at Sensor 2 (˚C)
%3 = Temperature at Sensor 3 (˚C)
(ex.) %1 = 12.3˚C, %2 = 23.4˚C, %3 = 34.5˚C
--> The projector displays “12.3 23.4 34.5”
( For each sensor, two digit and the tenth place
numbers are displayed with a space between each
temperature.)
? Communication failure
The tables on pages 74 and 75 show the typical command lists for controlling the projector. Please consult your