VXI VM4016 Computer Hardware User Manual


 
VXI Technology, Inc.
26 VM4016 Programming
INPUT:DEBOUNCE
The INPut:DEBounce command sets the time period for the digital debounce circuitry. This
command affects all the 16 channels of the instrument. It is important to note that the debounce
resolution is 9.6
µ
s.
INPut:DEBounce <value> Where <value> ranges from 9.6
µ
s, i.e.,
0.0000096 s to 0.6291456 s.
EXAMPLES
INPut:DEBounce 9.6e-6 Sets the input debounce time for all
channels to 0.0000096 s. This will not
allow a signal to generate an interrupt
unless the input signal crosses the signal for
more than 9.6 e-6 seconds.
INP:DEB 0.6 Setting input debounce time to 0.6 s.
INP:DEB? Returns the input debounce time as 0.6 s.
0.6