Detailed Description
See “3. 128 Mb Platform Flash XL,” page 20 and “4. 32 MB Linear BPI Flash,” page 20 for
details.
19. VITA 57.1 FMC HPC Connector
The ML605 implements both the High Pin Count (HPC, J64) and Low Pin Count (LPC, J63)
connector options of VITA 57.1.1 FMC specification. This section discusses the FMC HPC
J64 connector.
The FMC standard calls for two connector densities: a High Pin Count (HPC) and a Low
Pin Count (LPC) implementation. A common 10 x 40 position (400 pin locations) connector
form factor is used for both versions. The HPC version is fully populated with 400 pins
present, and the LPC version is partially populated with 160 pins.
The 10 x 40 rows of a FMC HPC connector provides connectivity for:
160 single-ended or 80 differential user-defined signals
10 MGTs
2 MGT clocks
4 differential clocks
159 ground, 15 power connections
Of the above signal and clock connectivity capability, the ML605 implements the following
subset:
78 differential user defined pairs:
34 LA pairs
24 HA pairs
20 HB pairs
8 MGTs
2 MGT clocks
4 differential clocks
Table 1-27: Switch S2 Configuration Details
Switch Configuration Mode/Method
Switch Net Name
JTAG
System ACE CF
Slave SelectMAP
Platform Flash XL
Master BPI
P30 Linear Flash
S2.1 CCLK_EXTERNAL Off On Off
S2.2 P30_CS_SEL On
(1)
Off On
S2.3 FPGA_M0 On Off Off
S2.4 FPGA_M1 Off On On
S2.5 FPGA_M2 On On Off
S2.6 FLASH_A23 Off Don't Care Off
(2)
Notes:
1. In JTAG mode, S2.2 is shown as ON for FPGA access to the P30 Linear Flash. Alternatively, set S2.2 to
OFF for FPGA access to the Platform Flash XL.
2. In Master BPI mode, S2.6 is shown as OFF for selecting initial configuration from BPI address
0x000000. Alternatively, set S2.6 to ON to select initial configuration from BPI address 0x800000.