Accton Technology ES3526XA Switch User Manual


 
Multicast Filtering Commands
4-217
4
Default Setting
2 times
Command Mode
Global Configuration
Command Usage
The query count defines how long the querier waits for a response from a
multicast client before taking action. If a querier has sent a number of queries
defined by this command, but a client has not responded, a countdown timer
is started using the time defined by ip igmp snooping query-max-
response-time. If the countdown finishes, and the client still has not
responded, then that client is considered to have left the multicast group.
Example
The following shows how to configure the query count to 10:
Related Commands
ip igmp snooping query-max-response-time (4-218)
ip igmp snooping query-interval
This command configures the query interval. Use the no form to restore the default.
Syntax
ip igmp snooping query-interval seconds
no ip igmp snooping query-interval
seconds - The frequency at which the switch sends IGMP host-query
messages. (Range: 60-125)
Default Setting
125 seconds
Command Mode
Global Configuration
Example
The following shows how to configure the query interval to 100 seconds:
Console(config)#ip igmp snooping query-count 10
Console(config)#
Console(config)#ip igmp snooping query-interval 100
Console(config)#