ADIC 601356 Barcode Reader User Manual


 
Command Reference
2-78 Command Reference 601356 Rev A
Return Codes
•0 - The vslock command is successfully processed.
-1 - An error is detected by either the CLI software or the
API software.
>0 - An error is detected by VolServ. The returned exit code
corresponds to the error code given by VolServ.
-h Requests help for the entered command.
When the Help option is specified, no
command line processing is performed.
An exit code of 0 is returned to the client when
the Help option is specified.
-H hostname Host name of the VolServ server. The default
host name is the host name of the computer
where the CLI command is run.
-P priority
Default value is
15.
The execution priority of the entered
command. Assignable priority values are
restricted to a range from 1 (highest) to 32
(lowest) inclusive.
-R retries
Default value is
3.
Number of retries the CLI software attempts if
a time-out is returned by the API software.
-T timeout
Default value is
120 seconds.
Amount of time (in seconds) the API software
waits for status from VolServ before returning
a time-out to the CLI software. Total wait time
for a command is (retries plus 1) multiplied by
time-out value.
-V prognum
Default value is
300016.
RPC program number for VolServ.
Parameter Description