Commands
vsaudit
Performs library inventory verification.
If the specified library is robotically controlled, the robot
scans each physical bin location and verifies that the
database is consistent with the actual location of media. Any
noted inconsistencies are returned to the client, logged in a
system log file, and VolServ initiates corrective action,
based on the circumstances of the discrepancy.
However, if the specified library is a manually controlled,
the library operator is directed to generate the audit report.
The operator then directs the report to be printed or to verify
the information online. Either way, the operator performs
the inventory and corrects any reported discrepancies.
Discrepancies are resolved by issuing appropriate media
management commands (for example, Eject) to relocate
media to the appropriate locations. Audits of manual
libraries do not return a discrepancy list.
Although audit requests from the command line are for full
library audits only, subset audits can be performed from the
GUI.
Parameters
vsaudit archivename
[ -Ih ]
[ -H hostname ]
[ -P priority ]
[ -R retries ]
[ -T timeout ]
[ -V prognum ]
Tip
Full archive audits are lengthy and should be requested with
discretion.