ADIC 601356 Barcode Reader User Manual


 
Command Reference
2-46 Command Reference 601356 Rev A
Return Codes
•0 - The vsdismount command is successfully processed.
-1 - An error is detected by either the CLI software or the
API software.
>0 - An error is detected by VolServ. The returned exit code
corresponds to the error code given by VolServ.
Examples
Step 1. Successful dismount. Requests VolServ to dismount
MED032 from drive 2.
Step 2. Output returned:
-R retries
Default value is
3.
Number of retries the CLI software attempts if
a time-out is returned by the API software.
-T timeout
Default value is
120 seconds.
Amount of time (in seconds) the API software
waits for status from VolServ before returning
a time-out to the CLI software. Total wait time
for a command is (retries plus 1) multiplied by
time-out value.
-V prognum
Default value is
300016.
RPC program number for VolServ.
Parameter Description
vsdismount MED012 -d 2
Dismount of Media [MED032] from Drive
[2] was successful