ADIC 601356 Barcode Reader User Manual


 
Command Reference
2-44 Command Reference 601356 Rev A
vsdismount
Dismounts media from a drive.
For automated libraries, VolServ checks to see that the
media is ejected from the drive by the storage subsystem. If
the media is not ejected from the drive, the vsdismount
request fails and VolServ returns a failure status to the
client. However, if the media is ejected from the drive,
VolServ tells the library robotics to move the media from
the drive pickup point to a bin within the library system. A
successful return code is returned to the client after the
media movement is completed.
For manual libraries, a dismount notice is sent to the
appropriate library’s console display for action. An operator
dismounts the specified media and then notifies VolServ that
the media dismount is complete. VolServ returns a
successful return code to the client only after the operator
confirms the dismount is complete.
Parameters
vsdismount mediaid
vsdismoun-d driveid
[-l lockid]
[-u usagetime]
[-e errorcount]
[ -Ih ]
[ -H hostname ]
[ -P priority ]
[ -R retries ]
[ -T timeout ]
[ -V prognum ]