ADIC 601356 Barcode Reader User Manual


 
Command Reference
2-18 Command Reference 601356 Rev A
Parameters
Parameters Description
archivename Specifies the name of the archive to audit.
Valid archive names may contain up to 16
alphanumeric characters, including spaces.
Leading and trailing spaces are not
permitted.
-I Command options are first read from the
command line. VolServ then reads any
options contained in the stdin file.
-h Requests help for the entered command.
When the Help option is specified, no
command line processing is performed.
An exit code of 0 is returned to the client when
the Help option is specified.
-H hostname Host name of the VolServ server. The default
host name is the host name of the computer
where the CLI command is run.
-P priority
Default value is
15.
The execution priority of the entered
command. Assignable priority values are
restricted to a range from 1 (highest) to 32
(lowest) inclusive.
-R retries
Default value is
3.
The number of retries the CLI software
attempts if a time-out is returned by the API
software.
-T timeout
Default value is
120 seconds.
Amount of time (in seconds) the API software
waits for status from VolServ before returning
a time-out to the CLI software. Total wait time
for a command is (retries plus 1) multiplied by
time-out value.