ADIC 601356 Barcode Reader User Manual


 
Command Reference
601356 Rev A Command Reference 2-51
Commands
Step 1. Unsuccessful drive query. Requests VolServ to
return information on drive 35. (Drive 35 does not
exist.)
Step 2. Output returned:
Notes
The vsdriveqry command does not trigger unsolicited status
messages from VolServ.
A pending vsdriveqry request is cancelled with the VolServ
cancel command. The VolServ cancel command is run from the
command line by sending a SIGQUIT signal (control-\). The
request also is aborted by sending the SIGINT signal
(control-c).
See Also
•vsdrivevary
-----------------------------------------------
Drive ID: 4
-----------------------------------------------
Drive Type: Magnetic
Associated Archive: shelf1
Current State: Online
Assignment: Free
Usage Count: 0
Current Usage Time: 0
Total Usage Time: 0
Error Count: 0
Mount State: Unmounted
Mounted Media ID:
Media Type(s) Supported:D2M
vsdriveqry 35
Drive query was unsuccessful.
Error VOL008: item not found.