ADTRAN MX410 Network Router User Manual


 
Remote Management of Other Systems using Terminal Server Ports and Ethernet Connectivity MX410/MX412 System Manual
3-18 PRELIMINARY 61189500L1-1B
Remote Management of Other Systems using Terminal Server
Ports and Ethernet Connectivity
In this application the Terminal Server ports on the MX410 are used to provide remote
management of other non-Ethernet based equipment at the same site. This requires
connecting the RS-232 craft ports of the other equipment to the Terminal Server ports of the
MX410. Establishing a Telnet session to the MX410 Terminal Server ports establishes access
to the other equipment. Up to four external devices can be accessed in this way.
The Ethernet ports on the MX410 are used to provide remote management of the other
Ethernet based equipment. This requires connecting the Ethernet ports of the other
equipment to the Ethernet ports on the MX410 (see Figure 3-23). Refer to “PPP BCP/IPCP
Menu” on page 5-32 for more information about PPP and IP.
Figure 3-23. MX410 Remote Management of Other Systems
The equipment needed for a Remote Management application is shown in Table 3-4.
Table 3-4. Remote Management Application - Required Equipment
Part Number Equipment Quantity
1189500L1
or
1189512L1
MX410
MX412
1
1
1189501L1 MX410 PSU (MX410 only) 1 (2 for redundancy)
Other Systems
Currently Managed
by the MX410 via
Ethernet Port to
Ethernet Port
Connections
Technician
Manages All
MX410 Units
and Other Systems
from Any Cell Site
Other Systems
Currently Managed
by the MX410 via
Terminal Server Port
to RS-232 Craft Port
Connections
MX410
IP
Ethernet Ports
Ethernet Ports
Terminal Server Ports
RS-232 Ports
DS1
µ Wave/
Leased
DS1
Original DS0s
Continue
Downstream;
All Ones in
Unmapped DS0s
DS1
µ Wave/
Leased
DS1
Original DS0s
Continue
Downstream;
All Ones in
Unmapped DS0s
DS1 DS1DS1 DS1
Ethernet
Switch
MX410