Allied Telesis AT-iMG646BD-ON Network Card User Manual


 
Chapter 3: Installing the Enclosure
50 Section I: Outdoor Installation
10. Temporarily secure the splice tray to the inside of the inner cover with
electrical tape until the gateway is installed, as shown in Figure 29.
Note
In cold climates, Allied Telesis recommends that you use 3M 3723
Cold Temp Tape.
Figure 29. Securing the Plastic Splice Tray
Note
The AT-iMG646BD-ON WAN module has a receive sensitivity of -3
dBm to -32 dBm at 1550 nm. After the fiber pigtail is installed and
before you plug the pigtail into the gateway, please check the power
of the optical input signal. The power at 1550 nm should fall within
the receive sensitivity specification. If the power is too high, an
optical attenuator is needed in the link. If the power is too low, you
must trace the optical path to determine the cause of the excess
loss.
Note
The AT-iMG646PX-ON WAN module has a receive sensitivity of -3
dBm to -26.5 dBm at 1490 nm. After the fiber pigtail is installed and
before you plug the pigtail into the gateway, please check the power
of the optical input signal. The power at 1490 nm should fall within
the receive sensitivity specification. If the power is too high, an
optical attenuator is needed in the link. If the power is too low, you
must trace the optical path to determine the cause of the excess
loss.
1184