Allied Telesis AT-iMG646BD-ON Network Card User Manual


 
Section I: Troubleshooting 87
Chapter 7
Troubleshooting
This chapter contains information on how to troubleshoot the gateway in
the event that a problem occurs.
Problem: Gateway is not operating correctly.
Solution: Reset the unit by disconnecting and then reconnecting the
power cable.
Problem: The PWR LED is off.
Solution: Check the power cable to verify that it is not damaged and that it
is connected correctly.
Problem: The SYST LED is on.
Solution: Unplug the power cable and plug it in again after 20 seconds. If
the LED does not turn off, unplug the power cable and contact Allied
Telesis.
Problem: The WAN LED is off.
Solution: Check the following:
Verify that the fiber optic port and FX fiber connector on the pigtail from
the splice tray are clean. Refer to Appendix B, “Cleaning Fiber Optic
Connectors” on page 91 for information.
Verify that the connector is properly seated in the fiber optic port.
Verify that the fiber optic cable has an active light source.
Problem: The VOIP LED remains off when you lift up the receiver on the
connected telephone.
Solution 1: Verify that the telephone cable is correctly connected, that the
correct cable is being used, and that the cable is not damaged.
Solution 2: Unplug the RJ-11 pigtail for the telephone circuit in question.
Plug a POTS telephone into the RJ-11 jack. If the VOIP LED lights up
when you lift the receiver, then there may be a problem with the telephone
cable. If the VOIP LED does not light up, then there may be a problem with
the AT-iMG646BD-ON gateway. Contact Allied Telesis.