Allied Telesis AT-PWR06 Switch User Manual


 
Stack Installation Guide for AT-2552XS L2 Data Center Switch
29
Console Port
The Console port is used to locally configure the features and parameter
settings of the switch. See Figure 2 on page 20 for the location of the
Console port. This type of management uses serial RS-232 and is
commonly referred to as local or out-of-band management because it is
not connected over an Ethernet network. To perform local management,
you must be at the location of the switch and must use the management
cable included with the switch.
To establish a local management session with the switch, you connect a
terminal or a personal computer with a terminal emulation program to the
Console port, which has a USB connector, using the provided
management cable, which has USB and DB-9 (D-sub 9-pin) connectors.
The Console port is set to the following specifications:
Default baud rate: 9600 bps (Range is 9600 to 115200 bps)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
These settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulation program.