NO DATA ON-SCREEN and/or REGISTER LED NOT FLASHING
1. Press the “Reset” button on the VSI-Pro Max front panel.
2. Incorrect register selected in the REGISTER SELECT menu.
3. Data cable is miswired.
4. Data cable is too long or did not use shielded cable.
5. May be connected to the wrong port.
6. Need RS-232 Optical Isolation so enable this feature in the VSI-Pro Max
REGISTER LED FLASHING but NO or Wrong DATA ON-SCREEN
1. Incorrect register selected in the REGISTER SELECT menu.
2. Baud Rate wrong, change to Auto Baud rate and do transaction
3. Interface Type set wrong
3. Data cable is miswired.
4. Data cable is too long or did not use shielded cable.
5. May be connected to the wrong port.
PROBLEMS WITH ECR / TPIF BOARDS
1. Upon regsiter power up verify on-screen ECR power up test.
2.Check that the board is seated properly in the register.
3. Check jumper settings on the board if applicable.
4. For ECR boards make sure the 2 pin data cable is plugged in correctly.
PROBLEMS WITH N2RS, NCR2RS, DTS2RS, B2RS ETC.
1. Check the cable to the register.
2. If VSI-Pro Max was working and stopped, power cycle the system. Turn off the register, unplug the power to the
N2RS, and unplug the power to the VSI-Pro. Now power up the system, plug in the VSI-Pro and the N2RS. Turn
on the register and do a transaction. The data should re-appear.
3. Check the cable between the VSI-Pro Max and the N2RS.
PROBLEM SOLVING GUIDE APPENDIX A
5.11 HELP
“HELP” on the main-menu provides a quick reference guide of the functions of the “Up” and “Down” and “Set”
buttons.
PROGRAMMING
Figure 101: HELP Sub-Menu
Key Definitions :
UP/DOWN _ _ Change value
SET _ _ Enter change mode
Save change
Go to position
UP AND DOWN _ _ Save string input
UP AND SET _ _ Erase character
VSI-Pro Max POS / Cash Register Interface