MVP Modero ViewPoint Touch Panels
Batteries Page
The options on this page allow you to set power warning preferences, monitor battery status information,
and adjust the display times for battery warnings. This page is populated with information from MVP-
BP batteries in the panel, as well as batteries in a connected MVP-TDS/WDS docking station (FIG. 49).
Features on this page include:
FIG. 49 Batteries page
Batteries Page
Back: Saves all changes and returns to the previous page.
Connection Status icon: The icon in the upper-right corner of each Setup page provides a constant
visual indication of current connection status.
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx
Master.
Battery Power Brightness
Limit:
The DISABLE/DISABLED button acts as a power save feature with two options:
Disable - activates the brightness limit set on the panel (conserves battery
power). Activating this feature causes the panel to function at 80% of full
brightness and overrides the Panel Brightness value set on the Setup page.
Disabled - deactivates this power save feature. The panel will use the Panel
Brightness level.
Note: This field applies to MVP-BP batteries installed in the panel.
Panel Shutdown: This value determines the number of minutes that would need to pass before
the panel automatically shuts-down. Once shutdown, the unit would have to be
restarted. The UP/DN buttons alter the timeout value (in minutes). A value of 0
disables this feature.
Range = 0 - 240, default = 1200 min.
Note: This field applies to MVP-BP batteries installed in the panel.
Low Battery Warning: The UP/DN buttons adjust the time value (in minutes) available on the battery
(for use) before the panel displays a low battery warning.
Range - 10 - 45, default = 15 min.