4 Locate the screws holding the main top cover in place (see Figure 5-9).
Remove the three screws and lift up on the screw mountings until the
cover is loose. Gently pull the cover up and to the left of the projector
until it releases.
OVERTEMP
VOLUME
SOURCE
FIT-TO-VIEW
POWER
CLEAR
SETUP
MENU
REPL LAMP
Figure 5-9, The three top cover screws
5 While still holding the cover, remove the ribbon cable on the underside
of the control panel. Place the cover on a soft cloth.
Caution! Never touch the LCD panel located underneath the top-cover
projection lens. Use caution when changing the filters.