8. Adjustments
Blanking
Top
Bottom
Left
Right
0
0
0
0
RESET
Enabled
Disabled
Image 8-20
Use the checkboxes to enable/disable the blanking
Use the Reset key to reset the blanking values.
The logo is also a
ffected by the blanking
8.13 Autosetup parameters
What can be done ?
The autose
tup can be done by using automatic adjustments of following parameters:
• Frequency : adjust automatically the total number of pixels of the detected source
• Phase : adjusts automatically the phase of the detected source
• Geometry : adjusts automatically the total number of lines of the selected source
• Gain : adjusts automatically the contrast/brightness settings of the selected source
All these parameters can be chosen to be taken in account or not during the Autosetup process, enabling or disabling the options is
done by checking or unchecking the corresponding case.
How to setup ?
1. Press MENU to activate the Toolbar
2. Press → to se
lect Adjustment
3. Press ↓ to Pull down the menu
4. Use ↑ or ↓ to select Autosetup parameters (image 8-21)
5. Press ENTER to activate the function
On the screen appears a dialogbox (image 8-22)
6. Use ↑ or ↓ to select the desired parameter, a box surrounds the selected item, press ENTER to activate
7. Press MENU or B
ACK to exit or to go back to the previous menu
60
R5976741 MGP 15 MEDICAL GRADE PROJECTOR 28/04/2004