10 0
OmniView IP 5000 HQ
TECHNICAL SPECIFICATIONS
SECTIONS
Table of Contents
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12
14
16
18
20 21
OmniView IP 5000HQ Manager
Form factor OmniView IP 5000HQ Manager 1U rack-mountable
Dimensions Height: 4.2cm (1.67 in.)
Width: 42.6cm (16.78 in.)
Depth: 29.7cm (11.7 in.)
With optional bezel: 69.3cm (27.29 in.)
Without optional bezel: 66cm (26 in.)
Weight (maximum
configuration kg.)
13.45kg. (29.6 lbs.)
Network connectors 2 x RJ45
Protocols HTTPS, XML, Telnet, SSH
OS Cent OS 5.0
Power supply 100–240VAC, 50–60Hz, auto-sensing
Client console Internet Explorer 6.0 or higher with JavaScript support
Certifications FCC, CE, CSA
Environmental
Temperature Operating: 10° to 35° C (50° to 95° F)
Storage: -40° to 65°C (-40° to 149° F)
Relative humidity Operating:20%to80%(non-condensing)withamaximumhumidity
gradationof10%perhour
Storage5%to95%(non-condensing)
Maximum vibration Operating: 0.26 Grms at 5–350Hz for 15 min.
Storage: 1.54 Grms at 10–250Hz for 15 min.
Maximum shock Operating: One shock pulse in the positive z axis (one pulse on each
side of the system) of 31 G for up to 2.6ms
Storage: Six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the system) of 71
G for up to 2ms
Altitude Operating: -16 to 3,048m (-50 to 10,000 ft.)
NOTE: For altitudes above 2,950 feet, the maximum operating
temperature is de-rated 1° F/550 feet.
Storage: -16 to 10,600m (-50 to 35,000 ft.)
Airborne
contaminant level
Class G2 or lower as defined by ISA-S71.04-1985