Bosch Appliances 3922 988 43318 Webcam User Manual


 
2
Bosch Security Systems | 04-2003 | 3922 988 43318 en
Digital Congress Network | Installation and Operating Manual | Chapter 5 - Control using PC
en | 5-10
Software configuration Master CCU PC (OS/2) (Serial Ports 1 and 2)
Table 5-7: Example CCU_CFG file for ‘DIRECT’ PC and
camera control
Location: C:\DCN\MCCU (default)
LOCATION CCU_0
LOCATION CCU_1
LOCATION CCU_2
LOCATION CCU_3
AUDIOMASTER CCU_1
CONTROLPC_CCU_0
INTERPRETER CCU_2
SERIALPORT1 2
SERIALSPEED1 19200
SERIALPROTOCOL1 CAMERA
SERIALPORT2 1
SERIALSPEED2 115200
SERIALPROTOCOL2 FULL
Table 5-8: Single COM-port only (default COM 2)
Function Single COM-port only (Port 1)
Remote control SERIALPORT1 2
SERIALSPEED1 19200
SERIALPROTOCOL1 SIMPLE
Camera control
(default)
SERIALPORT1 2
SERIALSPEED1 19200
SERIALPROTOCOL1 CAMERA
DCN PC control SERIALPORT1 2
SERIALSPEED1 115200
SERIALPROTOCOL1 FULL
RS232
COM2COM1
SERIALPORT1 2
SERIALSPEED1 19200
SERIALPROTOCOL1 CAMERA
CCU_CFG file setting
To CCU (Port 2)
CAMERA control (default)
Table 5-9: Two COM-ports (Port 1 and Port 2)
COM-port
functionality
Remote control Camera control DCN PC Control
Port 1: Remote control
Port 2 Camera control
SERIALPORT2 1
SERIALSPEED2 19200
SERIALPROTOCOL2 SIMPLE
SERIALPORT1 2
SERIALSPEED1 19200
SERIALPROTOCOL1 CAMERA
Not applicable
Port 1: DCN PC control
Port 2 Camera control
Not applicable SERIALPORT1 2
SERIALSPEED1 19200
SERIALPROTOCOL1 CAMERA
SERIALPORT2 1
SERIALSPEED2 115200
SERIALPROTOCOL2 FULL
Port 1: DCN PC control
Port 2 Remote control
SERIALPORT1 2
SERIALSPEED1 19200
SERIALPROTOCOL1 SIMPLE
Not applicable SERIALPORT2 1
SERIALSPEED2 115200
SERIALPROTOCOL2 FULL
The settings for each COM-port shall be present in the CCU_CFG file: (see below)
RS232RS232
COM2COM1
CCU_CFG file settings
SERIALPORT2 1
SERIALSPEED2 115200
SERIALPROTOCOL2 FULL
SERIALPORT1 2
SERIALSPEED1 19200
SERIALPROTOCOL1 CAMERA
Master CCU PC
Control PC Allegiant video switcher