Brother HL-1050 Printer User Manual


 
IV-6
I-2 Dark
Possible cause Step Check Result Remedy
HV.GND
contacts
(Fig.4-5)
Corona failure
(soiled wire)
1 Is the corona wire dirty? Yes Clean the corona wire
by using the wire
cleaner.
Corona failure
(contact failure)
2 Are the corona electrodes
between the printer body and
drum unit dirty?
No Clean both electrodes.
Drum unit failure 3 Is the problem solved when the
drum unit is replaced?
Yes Replace the drum
unit with a new one.
High-voltage
power supply
PCB
4 Are there any disconnected
connectors?
No Replace the high-
voltage power supply
PCB.
Main PCB 5 Are there any disconnected
connectors?
No Replace the main
PCB.
Panel sensor
PCB
6 Are there any disconnected
connectors?
No Replace the panel
sensor PCB.