Buffalo Technology TSXE80TLR5 Computer Hardware User Manual


 
TeraStation User Manual 147
Status
Displays the current status when changing the settings or formatting drives.
Examples of LCD Meaning
HDx Warning I11
Bad Sectors
Bad sectors in Xth hard drive may reach the dangerous zone. Replace Xth hard drive.
Operation Mode I12
DEGRADE MODE
RAID Degrade mode is running.
RAID I13
ARRAYx Formatting
Formatting Xth RAID Array.
RAID I14
ARRAYx Checking
Checking Xth RAID Array.
RAID I15
ARRAYx Scanning
Investigating the error status occurred in Xth RAID array.
* During the investigation, transfer speed will be degraded.
RAID I16
ARRAYx Creating
Creating Xth RAID Array.
RAID I17
ARRAYx Resyncing
Resyncing Xth RAID Array.
* While resyncing, the transfer speed will be degraded.
RAID I18
ARRAYx Rebuilding
Rebuilding Xth RAID Array.
* While rebuilding, the transfer speed will be degraded.
RAID I19
ARRAYx 0 Filling
Deleting data completely by lling 0 into Xth RAID array.
DISK I20
DISKx Formatting
Formatting Xth hard drive.
DISK I21
DISKx Checking
Checking Xth hard disk.
DISK I22
DISKx 0 Filling
Deleting data in Xth hard drive.
SYSTEM I23
Initializing
Initializing the system.
Network I24
Setting Cong
Setting the network such as obtaining an IP address.
SYSTEM I25
F/WUPDATING
Updating the TeraStation’s rmware.
* Do not turn o the TeraStation while updating.
Web Setting I26
Initializing
Initializing web conguration.
USB Diskx I27
Checking
Checking Xth USB hard disk.
USB Diskx I28
Formatting
Formatting Xth USB hard drive.
Press FuncSW I31
New Diskx ready
This message is displayed when restructure RAID by pressing a function switch after
replacing the hard drive.
Set From Web I32
New Diskx ready
This is displayed when RAID needs to be restructured on the Web Admin interface or
formatted after replacing the hard drive.
* If you are using TS-RXL Series, LCD display with the height of 1 line contains 2 line’s worth of information. You can scroll horizontally
to view it.