35
Detail: Manual Access To
• Function:
Sets a designated sharpness position, which is determined by the parameter of this command. The result is the same
as rotating the manual control knob on the front panel.
Note:
The control knob’s physical position is not updated by this command.
This command simply modifies the target exposure default value which is $80.
• Available parameter value:
LSH: $ 00 (less detail)~ $ FF (more detail)
• Timing of the “C-response Packet” sent to the PC:
Right after the sharpness is adjusted.
• The parameter of the “C-response Packet”:
$0000 fixed
• The maximum operation time (msec):
500 millisecond
• Command format:
$10 $ 8 * $3 0 $ 0 0 $ * *
Header ID number Command Parameter MSH Parameter LSH
3.5 Detail Commands