41
LED: Normal
• Function:
The LED indicated by the parameter data will be set to normal operation. This command is available in the
[N
OTIFICATION
] Mode. If the RE-350 receives this command from the PC in another mode, the RE-350 will send a
“C-response Packet” with the Mode Error response.
• The available parameter value:
LSH: $00 ~ $FF
• Timing of the “C-response Packet” sent to the PC:
Right after this setting is done.
• The parameter of the “C-response Packet”:
$0000 fixed
• The maximum operation time (msec):
500 millisecond
• Command format:
Header ID number Command Parameter MSH Parameter LSH
$10 $ 8 * $ 6 8 $ * * $ 0 0
RS-232 Input select NEGA WB Auto B/W Focus Auto Lights Backlight
D15 D14 D13 D12 D11 D10 D9 D8
• The bit assignment for the parameter data:
Each bit corresponds to each LED on the operation panel.