Canon RE-350 Webcam User Manual


 
50
Status of EXP control knob
Function:
Gets the position data of the EXP control knob. (EXP = exposure)
Timing of the C-response Packet sent to the PC:
Right after this command is received by the RE-350.
The parameter of the C-response Packet:
MSH: $00 fixed LSH: $00 ~ $FF
The maximum operation time (msec):
100 millisecond
Command format:
Header ID number Command Parameter MSH Parameter LSH
$10 $ 8 * $ 82 $ 0 1 $ 0 0
Status of WB control knob
Function:
Gets the position data of the White Balance Manual control knob.
Timing of the C-response Packet sent to the PC:
Right after this command is received by the
RE-350.
The parameter of the C-response Packet:
MSH: $00 fixed LSH: $00 ~ $FF
The maximum operation time (msec):
100 millisecond
Command format:
Header ID number Command Parameter MSH Parameter LSH
$10 $ 8 * $ 82 $ 0 0 $ 0 0