53
Set to Special Mode 1
• Function:
Lets the RE-350 transfer to Special Mode 1. The RE-350 will accept this command independently from its ID
number.
• Timing of the “C-response Packet” sent to the PC:
Right after this command is received by the RE-350.
• The parameter of the “C-response Packet”:
MSH: $00 fixed LSH: $00 fixed
• The maximum operation time (msec):
100 millisecond
• Command format:
Header ID number Command Parameter MSH Parameter LSH
$10 $ 8 * $F 0 $ 0 0 $ 0 0
Note: This command is prepared for service purposes ONLY and it is not
intended for use by the end-user.
Set to Special Mode 2
• Function:
Lets the RE-350 transfer to Special Mode 2. The RE-350 will accept this command independently from its ID
number.
• Timing of the “C-response Packet” sent to the PC:
Right after this command is received by the RE-350.
• The parameter of the “C-response Packet”:
MSH: $00 fixed LSH: $00 fixed
• The maximum operation time (msec):
100 millisecond
• Command format:
Header ID number Command Parameter MSH Parameter LSH
$10 $ 8 * $F 1 $F F $ 0 0
Note: This command is prepared for service purposes ONLY and it is not
intended for use by the end-user.