Cisco Systems 1300 Series Network Router User Manual


 
7-3
Cisco Aironet 1300 Series Outdoor Access Point/Bridge Hardware Installation Guide
OL-5048-02
Chapter 7 Troubleshooting
Checking the LEDs
The access point/bridge uses a blinking code to identify various error conditions. The code sequence uses
a two-digit diagnostic code that starts with a long pause to delimit the code, followed by the LED
flashing red to count out the first digit, then a short pause, followed by the LED flashing red to count out
the second digit.
Blinking
green
Root bridge mode—no remote bridges are associated.
Non-root bridge mode—not associated to the root bridge.
If all bridges are powered up, this could be caused by incorrect SSID
and security settings or improper antenna alignment. You should check
the SSID and security settings of all bridges and verify antenna
alignment.
If the problem continues, contact technical support for assistance.
Green Root mode—associated to at least one remote bridge.
Non-root mode—associated to the root bridge.
This is normal operation.
Blinking
amber
General warning—disconnect and reconnect the power injector power
jack. If the problem continues, contact technical support for
assistance.
Amber Loading firmware.
Red Amber Red Loading Firmware error—disconnect and reconnect the power injector
power. If the problem continues, contact technical support for
assistance.
Off Normal operation.
Blinking
green
Transmitting and receiving radio packets—normal operation.
Blinking
amber
Maximum retries or buffer full occurred on the radio
interface—disconnect and reconnect the power injector power jack. If
the problem continues, contact technical support for assistance.
Amber Radio firmware error—disconnect and reconnect power injector
power. If the problem continues, contact technical support for
assistance.
——Amber
blinking
Not associated (non-root mode). The access point/bridge attempts to
associate with a root bridge for 60 seconds
1
.
Amber Associated (non-root mode).
Green
blinking
Not associated (root mode). The access point/bridge attempts to
associate with a non-root bridge indefinitely.
Green Associated (root mode).
Red Overcurrent or overvoltage error—disconnect power to the power
injector, check all coax cable connections, wait approximately 1
minute, and reconnect power. If error continues, contact technical
support.
1. Preconfigured bridges search indefinitely.
Table 7-1 LED Indications (continued)
Ethernet
LED
Status
LED
Radio
LED
Install
LED
Meaning