Cisco Systems 15454 SDH Network Router User Manual


 
A-11
Cisco ONS 15454 SDH Reference Manual, R5.0
April 2008
Appendix A Hardware Specifications
A.4.6 AIC-I Specifications
Severity customer provisionable
Common 32-V output for all alarm-inputs
Each input limited to 2 mA
Termination via MIC-A/P
Alarm outputs
Number of outputs: 4 (user configurable as inputs)
Switched by opto-MOS (metal oxide semiconductor)
Triggered by definable alarm condition
Maximum allowed open circuit voltage: 60 VDC
Maximum allowed closed circuit current: 100 mA
Termination via MIC-A/P
EOW/LOW
ITU-T G.711, ITU-T G.712, Telcordia GR-253-CORE
A-law, mu-law
Note Due to the nature of mixed coding, in a mixed-mode configuration (A-law/mu-law) the
orderwire is not ITU-T G.712 compliant.
Orderwire party line
Dual tone multifrequency (DTMF) signaling
User data channel (UDC)
Bit rate: 64 kbps, codirectional
ITU-T G.703
Input/output impedance: 120 ohms
Termination: RJ-11 connectors
Generic communications channel (GCC)
Bit rate: 576 kbps
EIA/TIA-485/V11
Input/output impedance: 120 ohms
Termination: RJ-45 connectors
ACC connection for additional alarm interfaces
For future use
Environmental
Operating temperature: –40 to +65 degrees Celsius (–40 to +149 degrees Fahrenheit)
Operating humidity: 5 to 95%, noncondensing
Power consumption: 8.00 W, 0.17 A, 27.3 BTU/hr
Dimensions
Height: 321.3 mm (12.650 in.)