A-11
Cisco ONS 15454 SDH Reference Manual, R5.0
April 2008
Appendix A Hardware Specifications
A.4.6 AIC-I Specifications
–
Severity customer provisionable
–
Common 32-V output for all alarm-inputs
–
Each input limited to 2 mA
–
Termination via MIC-A/P
• Alarm outputs
–
Number of outputs: 4 (user configurable as inputs)
–
Switched by opto-MOS (metal oxide semiconductor)
–
Triggered by definable alarm condition
–
Maximum allowed open circuit voltage: 60 VDC
–
Maximum allowed closed circuit current: 100 mA
–
Termination via MIC-A/P
• EOW/LOW
–
ITU-T G.711, ITU-T G.712, Telcordia GR-253-CORE
–
A-law, mu-law
Note Due to the nature of mixed coding, in a mixed-mode configuration (A-law/mu-law) the
orderwire is not ITU-T G.712 compliant.
–
Orderwire party line
–
Dual tone multifrequency (DTMF) signaling
• User data channel (UDC)
–
Bit rate: 64 kbps, codirectional
–
ITU-T G.703
–
Input/output impedance: 120 ohms
–
Termination: RJ-11 connectors
• Generic communications channel (GCC)
–
Bit rate: 576 kbps
–
EIA/TIA-485/V11
–
Input/output impedance: 120 ohms
–
Termination: RJ-45 connectors
• ACC connection for additional alarm interfaces
–
For future use
• Environmental
–
Operating temperature: –40 to +65 degrees Celsius (–40 to +149 degrees Fahrenheit)
–
Operating humidity: 5 to 95%, noncondensing
–
Power consumption: 8.00 W, 0.17 A, 27.3 BTU/hr
• Dimensions
–
Height: 321.3 mm (12.650 in.)