Cisco Systems RJ-45-to-AUX Switch User Manual


 
[D] Fourth WRITE manager name or IP address
[X] Exit to previous menu
At this point you can select option [1] and configure the WRITE community string and change the
default community string from “private” to “techwrite,” as we did in the following:
Catalyst 1900 − Network Management (SNMP) WRITE Configuration
—————————————————————— Settings ——————————————————
[1] First WRITE community string
[2] Second WRITE community string
[3] Third WRITE community string
[4] Fourth WRITE community string
[A] First WRITE manager name or IP address 63.78.39.84
[B] Second WRITE manager name or IP address
[C] Third WRITE manager name or IP address
[D] Fourth WRITE manager name or IP address
[X] Exit to previous menu
Enter Selection: 1
This command configures the community string the switch will recognize on all SNMP read/write (Get/Set) requests. The string can be from 1 to 32 characters. Any character with a legal keyboard representation is allowed.
Enter WRITE community string:
Current setting ===> private
New setting ===> techwrite
7.
Again, once you have entered the new setting, your screen will automatically refresh. At this point,
enter option [X] and return to the SNMP configuration menu.
8.
At the Network Management (SNMP) Configuration Menu, select [T]. This will allow you to
configure the trap message configuration settings:
Catalyst 1900 − Network Management (SNMP) Configuration
[R] READ configuration
[W] WRITE configuration
[T] TRAP configuration
[X] Exit to previous menu
Enter Selection: T
Catalyst 1900 − Network Management (SNMP) TRAP Configuration
——————————— Settings ——————————————————
[1] First TRAP community string
[A] First TRAP manager name or IP address
[2] Second TRAP community string
[B] Second TRAP manager name or IP address
[3] Third TRAP community string
[C] Third TRAP manager name or IP address
[4] Fourth TRAP community string
[D] Fourth TRAP manager name or IP address
[U] Authentication trap generation Enabled
[L] LinkUp/LinkDown trap generation Enabled
[X] Exit to previous menu
Enter Selection:
9.