Citizen CL-S700 Label Maker User Manual


 
Chapter 4 Troubleshooting
4-2. Troubleshooting
CL-S700/CL-S703/CL-S700R 4-14
4-2-7. Rewinder Problems (CL-S700R Only)
(1) Rewinding problem (CL-S700R Only)
Symptoms Checks Remedies
Does not rewind. 1. Is the rewinder cover opened?
In this case, the LCD indicates “Error
Rewinder Open”.
2. Is the rewinder full?
In this case, the LCD indicates “Error
Rewinder Full”.
3. Is the rewinder motor over heated?
In this case, the LCD indicates “Alarm
Rewinder Hot”.
4. Are cables J15 and J16 (“SA, Main
PCB”) connected to J501 and J502
(“SA, Rewinder PCB”) firmly?
5. Is the connector of the “SA, Rewinder
Motor” connected to J504 of the “SA,
Rewinder PCB” firmly?
6. Is the connector of the “SA, Interlock
SW” connected to “SA, Rewinder
Motor” firmly?
In this case, the LCD indicates “Error
Rewinder Open”.
7. Failure in the “SA, Rewinder Motor”.
8. Failure in the “SA, Rewinder PCB”.
9. Failure in the control circuit.
1. Close the rewinder cover.
2. Remove the wound media from the
rewinder flange.
3. Wait until the rewind motor gets
cool. Rewinding resumes
automatically.
4. Connect them firmly.
5. Connect it firmly.
6. Connect it firmly.
7. Replace the “SA, Rewinder Motor”.
8. Replace the “SA, Rewinder PCB”.
9. Replace the “SA, Main PCB”.
Label is peeled but
rewinding operation
does not pause.
1. Is the peel sensor cable connected to
JP503 of the “SA, Rewinder PCB”
firmly?
2. Failure in the “SA, Rewinder PCB”.
3. Failure in the control circuit.
1. Connect it firmly.
2. Replace the “SA, Rewinder PCB”.
3. Replace the “SA, Main PCB”.