Running Cable Diagnostics
The
Diagnostics
page contains links to pages for performing virtual cable tests on copper cables.
To open the
Diagnostics
page, click
System
Diagnostics
in the tree view.
Viewing Copper Cable Diagnostics
The
Copper Cables
page contains fields for performing tests on copper cables. Cable testing
provides information about where errors occurred in the cable, the last time a cable test was
performed, and the type of cable error which occurred. The tests use Time Domain Reflectometry
(TDR) technology to test the quality and characteristics of a copper cable attached to a port.
Cables up to 120 meters long can be tested. Cables are tested when the ports are in the down state,
with the exception of the Approximated Cable Length test.
To open the
Copper Cables
page, click
System
Diagnostics
Copper Cable
in the tree view.
Figure 6-36. Copper Cables
The
Copper Cables
page contains the following fields:
Port
— The port to which the cable is connected.
Test Result
— The cable test results. The possible field values are:
No Cable
— There is no cable connected to the port.
Open Cable
— The cable is connected on only one side.
Short Cable
— A short has occurred in the cable.
OK
— The cable passed the test.