Dell QHB Webcam User Manual


 
Error Code Message Information
TMP0118
Message The system inlet temperature is less than the lower warning
threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0119
Message The system inlet temperature is less than the lower critical
threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0120
Message The system inlet temperature is greater than the upper
warning threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too warm or one or more fans
may have failed.
Action Check the system operating environment and review event
log for fan failures.
TMP0121
Message The system inlet temperature is greater than the upper
critical threshold.
LCD Message System inlet <name> temperature is outside of range. Check
Fans.
Details Ambient air temperature is too warm or one or more fans
may have failed.
Action Check the system operating environment and review event
log for fan failures.
TMP0122
Message The system inlet temperature is outside of range.
LCD Message System inlet <name> temperature is outside of range. Check
Fans.
Details Ambient air temperature is too warm or cool.
Action Check the system operating environment and review event
log for fan failures.
123