Dell QHB Webcam User Manual


 
Error Code Message Information
Details Chassis power level current is outside of the optimum range.
Action
1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see Getting Help.
ASR0000
Message The watchdog timer expired.
Details The operating system or an application failed to
communicate within the time-out period.
Action Check the operating system, application, hardware, and
system event log for exception events.
ASR0001
Message The watchdog timer reset the system.
Details The operating system or an application failed to
communicate within the time-out period. The system was
reset.
Action Check the operating system, application, hardware, and
system event log for exception events.
ASR0002
Message The watchdog timer powered off the system.
Details The operating system or an application failed to
communicate within the time-out period. The system was
shut down.
Action Check the operating system, application, hardware, and
system event log for exception events.
ASR0003
Message The watchdog timer power cycled the system.
Details The operating system or an application failed to
communicate within the time-out period. The system was
power-cycled.
Action Check the operating system, application, hardware, and
system event log for exception events.
ASR0008
Message The watchdog timer interrupt was initiated.
Details The operating system or an application failed to
communicate within the time-out period. No action was
taken.
72