AC Power Requirements
NOTES:
An X used above in the Model Numbers is a “wildcard” character meaning any valid character code combination.
Maximum line current requirement is specied at the minimum nominal AC line voltage and the rated power level.
Table 10- III AC Power Requirements
Operating
Frequency
Generator
Model Number
Overload
Power
Ratings
(Watts)
Input AC Power Requirements
Nominal AC Volt
@ Maximum RMS Current
North America/
Japan
AC Outlet Rating
15kHz 15HS360-2A-XX-XX 3600 200-240V 50/60 Hz @ 25 Amps
30 Amps
15kHz 15HS480-2A-XX-XX 4800 200-240V 50/60 Hz @ 30 Amps
20kHz 20HS120-1A-XX-XX 1200 100-120V 50/60 Hz @ 15 Amps
15 Amps
20kHz 20HS120-2A-XX-XX 1200 200-240V 50/60 Hz @ 8 Amps
20kHz 20HS180-2A-XX-XX 1800 200-240V 50/60 Hz @ 12 Amps
20kHz 20HS240-2A-XX-XX 2400 200-240V 50/60 Hz @ 15 Amps
20kHz 20HS360-2A-XX-XX 3600 200-240V 50/60 Hz @ 25 Amps
30 Amps
20kHz 20HS480-2A-XX-XX 4800 200-240V 50/60 Hz @ 30 Amps
30kHz 30HS090-1A-XX-XX 900 100-120V 50/60 Hz @ 8 Amps
15 Amps
30kHz 30HS090-2A-XX-XX 900 200-240V 50/60 Hz @ 8 Amps
30kHz 30HS120-1A-XX-XX 1200 100-120V 50/60 Hz @ 15 Amps
30kHz 30HS120-2A-XX-XX 1200 200-240V 50/60 Hz @ 8 Amps
30kHz 30HS180-2A-XX-XX 1800 200-240V 50/60 Hz @ 12 Amps
40kHz 40HS060-1A-XX-XX 600 100-120V 50/60 Hz @ 8 Amps
40kHz 40HS060-2A-XX-XX 600 200-240V 50/60 Hz @ 5 Amps
40kHz 40HS090-1A-XX-XX 900 100-120V 50/60 Hz @ 15 Amps
40kHz 40HS090-2A-XX-XX 900 200-240V 50/60 Hz @ 8 Amps
40kHz 40HS120-1A-XX-XX 1200 100-120V 50/60 Hz @ 15 Amps
40kHz 40HS120-2A-XX-XX 1200 200-240V 50/60 Hz @ 8 Amps
Page 113
Dukane Manual Part No. 403-575-00
Section 10 - Specications