Dukane 403-575-00 Power Supply User Manual


 
Lockout/Tagout
Procedure to use BEFORE making any internal
adjustments to the generator:
1. Push the generator's AC power switch/breaker
to the OFF position.
2. Unplug the generator's electrical cord from its
source.
3. Authorized personnel apply a lockout/
tagout (LOTO) device to the plug end of the
generator's electrical cord. Using a typical clam
shell type LOTO device:
1) Open the clam shell.
2) Place the electrical cord plug end inside the
shell.
3) Close the shell.
4) Secure the shell with its lock, and lock it.
4. Wait a minimum of ve minutes for the
generator to discharge its electrical energy.
5. After taking these steps, make the necessary
adjustments to the generator.
Assuming the generator is being put back into
service. . .
Procedure to use AFTER making any internal
adjustments to the generator:
1. Authorized personnel remove the lockout/
tagout device from the plug end of the
generator's electrical cord. Using a typical clam
shell type LOTO device:
1) Unlock the protective shell.
2) Open the shell, exposing the electrical cord
end.
3) Remove the LOTO device, and set it aside.
2. Plug the generator's electrical cord into its AC
power source.
3. Push the generator's AC power switch/breaker
to the ON position.
Continued from previous page
Page 14
iQ Series Ultrasonic Generator/Power Supply ES User’s Manual
Dukane Manual Part No. 403-575-00