Ultrasound Output Connector
The ultrasound output connector used with all standard
generators is a high voltage (5000V) coaxial style SHV-
BNC connector. This connector provides superior shielding
of electrical noise, compared to other types of connectors.
The ultrasound output connector mates with fully shielded
coaxial ultrasound cables that are secured with a simple and
reliable quarter-turn bayonet style attachment mechanism.
Figure 3-13 Ultrasound Output Connector
CAUTION
The ultrasonic output from
this connector (that drives
the attached ultrasonic load)
is a very high AC voltage
(1200VAC). At high power lev-
els this can exceed 2 amperes
of current and must be securely terminated
via the ultrasound cable for safe operation.
Use original equipment ultrasound cables
for safe and reliable system operation. Im-
properly assembled ultrasound cables can
result in high voltage arcing and will destroy
the ultrasound connectors.
Do not use your generator if there is any
evidence of arcing (black carbon deposits)
on either the ultrasound output connector
or the ultrasound cable connectors.
Conguration Port Connector
The conguration port connector is a DB-9M (standard
D-subminiature 9 circuit male) typically used for RS-232
serial communications. This serial port (DTE) connects to a
serial port (DCE) on a computer via a standard 9 pin serial
cable. If the computer does not have a serial port, you may
use a USB-to-serial conversion cable.
This port is used for eld updates to the generator rmware,
without removing the enclosure cover. This port can also be
used with a software application running on a Windows PC
to modify the factory default system settings and hardware
congurations. Contact your local sales representative for
software availability information and access to documenta-
tion that will allow you to make use of the conguration
port features.
Figure 3-14 Conguration Port Connector
Page 27
Dukane Manual Part No. 403-575-00
Section 3 - Installation