After pressing Teach, you will see a window similar to
the one shown in Figure 4-12.
Place an unwelded part into the xture. Press both opti-
touch activation switches to jog the horn down to within
0.010 - 0.030 inches above the part. The stroke position
of the thruster will be shown in the Current Position
box. Once you are at the desired position, press Set to
program that distance. Select Exit, and follow instruc-
tions to Home the machine.
Figure 4-13 iQ Explorer, Select Trigger Method
Select Trigger
Method,
Normal
Figure 4-12 iQ Explorer, Teach Start Sensing Distance
Servo Step 9 - Select Trigger Method
Still on the Process Settings tab, select Normal as the trigger
method.
Servo Step 8 - Teach Start Sensing Distance
Page 48
iQ Series Ultrasonic Generator/Power Supply ES User’s Manual
Dukane Manual Part No. 403-575-00