Epson 60 Printer User Manual


 
I/F CONFIG. (Interface Configuration)
This feature allows you to configure your printer’s channels to match the signals output
by your computer(s).
- Parallel Channel -
For the parallel channel, there are three settings. Normally, you do not have to change
any of these unless you have special requirements.
SLCTIN: If SLCTIN is OFF, the printer is continuously selected and ignores device
control codes DC1 and DC3. In almost all cases, leave SLCTIN set to OFF. When
SLCTIN is ON, the SLCTIN signal goes HIGH at power-up and control codes DC1
and DC3 are valid.
Available Options: ON, OFF
AUTOFEED: If AUTOFEED is OFF, the printer ignores the AUTOFEED signal on pin
14 and does not send an automatic line feed (LF) command with each carriage re -
turn (CR). If AUTOFEED is ON, the printer adds a line feed to each carriage return
that it receives. If your text lines overprint each other, set AUTOFEED to ON.
Available Options: ON, OFF
BUSY DELAY: Use this to set the delay period from the ACKNLG signal to the
BUSY signal.
Available Options: -5, 0, +5 (microseconds), MIN. The MIN option sets the
ACKNLG signal to HIGH.
Factory Settings: SLCTIN: OFF, AUTOFEED:OFF, BUSY DELAY: 0
Example procedure: To switch AUTOFEED on.
1. Enter Level 2 mode (see page 34).
2. Press or until I/F CONFIG. is displayed.
3.
4. Press or until CH P CONFIG. is dis -
played.
5.
6. Press or until AUTOFEED is displayed.
7. To change the current setting:
ADJUSTING THE PRINTER SETTINGS
35