Extron electronic 450 Plus Switch User Manual


 
4-7
CrossPoint 450 Plus and MAV Plus Switchers • SIS Programming and Control
PRELIMINARY
Symbol defi nitions
]
= CR/LF (carriage return/line feed) (hex 0D 0A)
}
= Carriage return (no line feed, hex 0D)
= Space character
E
= Escape key (hex 1B)
X!
= Input number 01 – (maximum number of inputs for your model)
X@
= Input number (for tie)
00 –
(maximum number of inputs for your model)
(00 = untied)
X#
= Output number 01 – (maximum number of outputs for your model)
X$
= Numeric dB value –18 to +24 (45 steps of gain or attenuation)
X%
= Audio gain 0 – 24 (1 dB/step)
X^
= Audio attenuation 1 – 18 (1 dB/step)
X&
= Volume adjustment range 0 – 64 (1 dB/step except for 0-to-1, which is 34.5 dB)
(see the table on page 4-11)
X*
= Room # (for room presets) 10 max. (each can have up to 10 presets (
X1@
s) assigned)
N
A Room is a subset of operator-selected outputs that relate to each other. The switcher supports up to 10 rooms, each of which can consist
of from 1 to 16 outputs.
X(
= Mute, executive mode, power supply (0 = off/not OK, 1 = on/OK)
X1)
= Group # (for I/O grouping) 1 through 4 groups (0 = no group)
X1!
= Global preset # 64 maximum (0 = current confi guration)
X1@
= Room preset # 10 maximum (0 = current confi guration for room)
N
A Room preset is a stored confi guration with all of the outputs assigned to a single room. When a room preset is retrieved from memory,
it becomes the current confi guration.
X1#
= RGB delay interval Delay in ½ second increments (10 maximum)
X1$
= Video/audio mute: 0 = no mutes
1 = video mute
2 = audio mute
3 = video and audio mute
X1%
= Sync frequency xxx.xx (frequency in Hz (V) or kHz (H))
X1^
= Signal detection 0 = no input detected, 1 = input detected)
X1&
= Firmware version number to second decimal place (x.xx)
X1*
= BME type 1 = wideband video
2 = low resolution video
3 = Sync
4 = stereo audio
5 = Mono audio
X1(
= # of connected BMEs in the system 1 through 6
X2)
= Verbose rmware version-description-upload date/time. See page 4-18.
X2!
= Name 12 characters maximum for global, room preset, input, and output names
11 characters maximum for room names
Upper- and lower-case alphanumeric characters and
_ : = / and spaces are valid.
N
The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X2@
= Voltage Positive or negative voltage and magnitude
X2#
= Temperature Degrees Fahrenheit
X2$
= Fan speed RPM