Extron electronic IPI 200 Series Switch User Manual


 
IPI 100 Series, IPI 200 Series • Programming and Control
IPI 201/204 SIS
Programming, cont’d
5-8
X4^
= E-mail recipient’s address (e.g.,
JDoe@extron.com) for the person to whom messages will be sent.
The e-mail address has a 31-character maximum.
X4&
= Name (numeral) of e-mail le to be sent
X4(
= Default name: a combination of the model name and the last 3 pairs of
the IPI 200 series’ MAC address
X5@
= Connection’s security level
11 = user
12 = administrator
X6#
= Pulse time in 20 ms per count. If this parameter is missing or = 0, then
pulse length = default = 25 = 500 ms. 1 = 20 ms (minimum pulse
time) to 65535 = 1310700 ms (maximum pulse time).
X6(
= IP connection timeout period in seconds. Each step is specied in 10-
second intervals (1 - 65000, default = 30 = 300 seconds). If no data
is received during the specied period, the Ethernet connection
closes. Responses are returned with leading zeros.
X7)
= The number to insert into an email message if a ____.eml le has an
embedded server-side include “<!--#echo var = “WCR
|
” -->”
(the
E
C R
}
command with no parameters.) The numeral is a
16-bit number to be employed as the user denes.
This is an optional parameter. Use 0 as a placeholder if the
optional
X4&
variable is used but
X7)
is not needed. Maximum
= 65535.
X7!
= Hardware (MAC) address: 4 most-signicant hex nibbles converted
into single 16-bit decimal number.
X7@
= Hardware (MAC) address: 8 least signicant hex nibbles converted
into single 32-bit decimal number.
N
This could be as large as 10 digits!).
X7#
= An e-mail account username of up to 31 characters. Do not use
commas. This parameter is optional during setup and is used for
SMTP authentication.
X7$
= An e-mail account password (for SMTP authentication) of up to 31
characters. Do not use commas. This parameter is optional
during setup.
X20^
= Voltage (in volts)
X20&
= Temperature in degrees Celsius (the response is 3 digits including
leading zeros)
X20(
= Front panel lockout (executive mode) status
0 = off/unlocked (default)
1 = on, disable/lock the front panel
X21&
= Firmware’s event status polling period from 0 to 255 in 20 ms
increments.
X21&
is optional: if it is not set, it defaults to 100
(2 seconds) and is not shown in the command’s response. If
X21&
is set to 0, the rmware does not poll for event status.
N
The event number that is polled is set by
X3%
in the EN
command.