IPI 100 Series, IPI 200 Series • Programming and Control
IPI 201/204 SIS
Programming, cont’d
5-14
Command ASCII (Telnet)
(host to intercom)
URL Encoded (Web)
(host to intercom)
Response
(intercom to host)
Additional
description
Request the
model name
1I 1I
IPI 201
]
IPI 204
]
Request the
model description
2I 2I
One-Button IP Intercom
]
Four-Button IP Intercom
]
Stand-alone IPI Intercoms
Request system
memory usage
3I 3I
# bytes used out of # of kbytes
]
or Inf03*# bytes used out of # of kbytes
]
Show amount of memory
used and total available
memory for system
operations.
Request user
memory usage
4I 4I
# bytes used out of # of kbytes
]
or Inf04*# bytes used out of # of kbytes
]
Show amount of user
memory used and total
available user memory.
Query IPI module 32I 32I
IPI201
]
IPI204
]
201 = IPI 201 AAP or 2-gang
204 = IPI 204 AAP or 2-gang.