IPI 100 Series, IPI 200 Series • Programming and Control
IPI 201/204 SIS
™
Programming, cont’d
5-12
Command ASCII (Telnet)
(host to intercom)
URL Encoded (Web)
(host to intercom)
Response
(intercom to host)
Additional
description
Query factory
rmware version
3Q 3Q
X1!
(kernel version–model description–date time of
upload)
]
or Ver03*
X1!
(kernel version–model description–date time
of upload)
]
Factory-installed rmware is
different from the bootstrap
rmware, but it is also
not user-replaceable. This
rmware was installed at the
factory; it is the version the
controller reverts to after a
mode 1 reset (see chpt. 2).
Example:
3Q 3Q 1.00(1.18-IPI 201/IPI 201/IPI 204 -Thu, 20 Jan 2005 09:41:47
GMT)
]
In this example the factory
rmware version
is 1.00 and the IP Link kernel
version is 1.18 for the IPI204,
dated 20 January 2005.