4-8
Command ASCII (Telnet)
(host to unit)
URL Encoded (Web)
(host to unit)
Response
(unit to host)
Additional description
View pass-thru
mode
24
EX!
CD
}
W
X!
CD
| X5)
,
X5#
,
X2!]
Ethernet data port
Set current connection
port timeout
E
0*
X6(
TC
}
W0%2A
X6(
TC
|
Pti0*
X6(]
The current port timeout period applies
to the currently open Telnet session only.
When you start another Telnet session, it
uses the default global port timeout period.
X6(
= timeout period in seconds. See
the description above. This variable is
applicable only when the IPL T S unit is
connected via Ethernet. If the IPL T S device
is connected via RS-232 protocol, only the
global timeout commands apply, and any
commands involving
X6(
return the E13
error response.
View current
connection port
timeout
E
0TC
}
W0TC
| X6(]
Set global IP port
timeout
E
1*
X6(
TC
}
W1%2A
X6(
TC
|
Pti1*
X6(]
The global port timeout is the default
timeout period for all Telnet sessions.
X6(
= IP connection timeout period
in seconds. Each step is specified
in 10-second intervals (1 - 65000,
default = 30 = 300 seconds). If no data is
received during the specified period, the
Ethernet connection closes. Responses are
returned with leading zeros.
This timeout period is applicable only
when the IPL T S unit is connected via
Ethernet, and you must be logged in as an
administrator to change this setting.
View global IP port
timeout
E
1TC
}
W1TC
| X6(]