Fluke 435 Power Supply User Manual


 
Fluke 434/435
Users Manual
20-12
2
Phase Colors: use the function keys F1 ... F4 to choose colors as used in
the USA, EU, UK, or according to IEC. Or define your own set of
colors: use the up/down arrow keys to select a phase and use the
left/right arrow keys to select a color. Press function key F5 – OK to
confirm.
3
Printer: Use the arrow keys to select and adjust baudrate for use with a
printer. Use the up/down arrow keys to select the printer type. Press
function key F5 – OK to confirm.
4
RS-232: Use the left/right arrow keys to adjust communication baudrate
(for communication with a PC).
5
Battery save: Use the up/down arrow keys to select the time after which
the Display dims when no keys are operated.
6
Configuration of Flash Memory: determines the amount of memory
available for data logging and screenshots/datasets. Use the up/down
arrow keys to select and ENTER to confirm.
7
F1 – FACTORY DEFAULTS: resets all settings in this menu to factory
default.
8
F2 – USER ID: access to a menu to define 3 lines with user
programmable text (e.g. the owner’s name and address). This text
appears in the power-on and SETUP entry screens. Use Function key
F3 to insert spaces. Press function key F5 – OK to confirm.
9
F3 – CONTRAST: Use left/right arrow keys to adjust the display
contrast.
10
F4 – CLEAR ALL MEMORY: All datasets, screens, and logging data
can be cleared in one action. Protection is achieved via a confirm menu.
11
F5 – BACK: return to SETUP entry menu.