110 Operating Manual BX400 S1
Hot-plug components
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9249-003.fm
8.2.10 Port assignment of the connection blades
The A-channels of the controllers in the server blades are connected to the
connection blade slots on the left-hand side (CB1 and CB3). The B-channels
are connected to the slots on the right-hand side (CB2 and CB4).
With the mezzanine cards, the assignment of the ports to the connection blade
slots can be defined via the management blade. The following figure shows the
different options.
mezzanine card Server blade slot (x) Connection blade slot (CB)
Mezzanine card slot (M) Port (P)
Port (P) Server blade slot (x)
FC 8 Gb/s
x.M1.P1 CB2.P1+(x-1)
x.M1.P2 CB2.P9+(x-1)
x.M2.P1 CB3.P1+(x-1)
x.M2.P2 CB4.P1+(x-1)
LAN 1 GbE (SB11, SB11A)
x.M1.P1 CB2.P1+2*(x-1)
x.M1.P2 CB2.P17+2*(x-1)
x.M1.P3 CB2.P2+2*(x-1)
x.M1.P4 CB2.P18+2*(x-1)
x.M2.P1 CB3.P1+2*(x-1)
x.M2.P2 CB4.P1+2*(x-1)
x.M2.P3 CB3.P2+2*(x-1)
x.M2.P4 CB4.P2+2*(x-1)
LAN 1 GbE (SB6)
x.M1.P1 CB2.P1+(x-1)
x.M1.P2 CB2.P9+(x-1)
x.M1.P3 -
x.M1.P4 -
x.M2.P1 CB3.P1+(x-1)
x.M2.P2 CB4.P1+(x-1)
x.M2.P3 -
x.M2.P4 -
Table 5: Port assignment of connection blades and mezzanine cards