20 Operating Manual BX400 S1
Introduction
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9242-003.fm
1.5 Technical data
Electrical data (hot-plug power supply unit)
Compliance with regulations and standards
Rated voltage range 100 - 240 V
Frequency 50 Hz-60 Hz
Max. rated current 45 A / 22.5 A (100-240 V)
Effective power 1785 W (240 V) 1200 W (100 V)
Apparent power 1821 VA (240 V) 1265 VA (100 V)
Heat dissipation 11520 kJ/h (with 3200 W) 5760 kJ/h
(with1600 W)
Main power fuse 16 A
Protection class I
Product safety and
ergonomics
IEC 60950-1 / EN 60950-1, UL/CSA 60950-1 (all
second edition is acquired)
CNS 14336 / GB 4943 / EN 50371
Electromagnetic
compatibility
GB 17625
interference
emissions
EN 55022 class A
Harmonic current EN 61000-3-2
Flicker EN 61000-3-3
interference
immunity
EN 55024, EN 300386
to EU directives Electromagnetic compatibility 2004/108/EC
Mechanical
environmental
conditions
EN 60721-3-3; class 3M2