BX400 S1 Operating Manual 39
Installing the hardware
4.3 Setting up the floorstand model
I If you are not installing a PRIMERGY BX400 S1 system unit floorstand
model, skip this section and continue reading at section
"Installing/removing the rack model" on page 40.
V CAUTION!
Follow the safety instructions in chapter "Important notes" on page 25.
Ê Transport the system unit to the place where you want to set it up.
Ê Unpack the system unit (see section "Unpacking the system unit" on
page 38).
Ê Set up the system unit.
V CAUTION!
– The device must be protected from direct sunlight.
– The essential minimum clearance for servicing must be
maintained.
– Access to the rear of the system unit must be assured so that
other devices (e.g. memory subsystems) can be connected.
– A clearance of at least 200 mm must be maintained in front of and
behind the system to ensure proper ventilation.
– The mains plug must be accessible easily and safely.
Ê Lock the casters.
Ê Wire the system unit. Read the information in section "Connecting devices
to the system unit" on page 49 and section "Instructions for
connecting/disconnecting cables" on page 54.
Ê Connect the system to the mains (see section "Connecting the system unit
to the mains" on page 51).