Fujitsu BX400 S1 Server User Manual


 
BX400 S1 Operating Manual 83
Hot-plug components
Installing a server blade
V CAUTION!
Make sure you observe the safety notes and the information on
handling electrostatic-sensitive devices in the section "Modules with
Electrostatic-Sensitive Devices" on page 32.
Beware of the energy hazard at the midplane contacts. A short circuit
on these contacts may damage the system.
The server blade boots automatically after installation in the
system unit.
When you install a server blade in an active system unit, the server
blade automatically performs a Power-On Self-Test (POST) and then
switches itself off.
If the system unit is switched off when you install the server blade, the
automatic POST is performed immediately after you switch on the
system unit.
Any unused server blade slots must be fitted with dummy modules to
comply with electromagnetic compatibility (EMC) regulations and to
ensure sufficient cooling of the system components.